<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Nelvin Electrical</title>
	<atom:link href="https://nelvinelectrical.com.au/feed/" rel="self" type="application/rss+xml" />
	<link>https://nelvinelectrical.com.au/</link>
	<description>Electrical Maintenance Solutions</description>
	<lastBuildDate>Wed, 29 Jun 2022 01:49:09 +0000</lastBuildDate>
	<language>en-AU</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>
	<item>
		<title>Solar Installations</title>
		<link>https://nelvinelectrical.com.au/solar-installations/</link>
		
		<dc:creator><![CDATA[fiona]]></dc:creator>
		<pubDate>Mon, 30 May 2022 04:24:26 +0000</pubDate>
				<category><![CDATA[Specialist Services]]></category>
		<guid isPermaLink="false">https://nelvinelectrical.com.au/?p=687</guid>

					<description><![CDATA[<p>The post <a href="https://nelvinelectrical.com.au/solar-installations/">Solar Installations</a> appeared first on <a href="https://nelvinelectrical.com.au">Nelvin Electrical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="et_pb_section et_pb_section_0 et_section_regular" >
				
				
				
				
				
				
				<div class="et_pb_row et_pb_row_0">
				<div class="et_pb_column et_pb_column_4_4 et_pb_column_0  et_pb_css_mix_blend_mode_passthrough et-last-child">
				
				
				
				
				<div class="et_pb_module et_pb_text et_pb_text_0  et_pb_text_align_left et_pb_bg_layout_light">
				
				
				
				
				<div class="et_pb_text_inner"><h2>Residential and Commercial Solar and Battery Installations</h2>
<p>Being a 100% local South Adelaide based company, we offer local onsite inspections to ensure accuracy of quotations. We will custom design the solar rooftop system to suit your requirements. We are Clean Energy Council (CEC) registered Designers, Installers and Electricians.</p>
<p>We offer very competitive pricing and will better any legitimate quotation. We use premium solar systems using Tier 1 inverters and panels. We apply Manufacturer&#8217;s Warranty on all equipment we install. We offer 5 years Guarantee on our workmanship.</p>
<p>We will endeavor to complete all installations as soon as possible after approval.</p>
<p>We also offer maintenance and service inspections on solar installations.</p>
<p>For any more information regarding Solar Installations please feel free to <a href="https://nelvinelectrical.com.au/contact/">contact Nelvin Electrical</a></p></div>
			</div>
			</div>
				
				
				
				
			</div>
				
				
			</div>
<p>The post <a href="https://nelvinelectrical.com.au/solar-installations/">Solar Installations</a> appeared first on <a href="https://nelvinelectrical.com.au">Nelvin Electrical</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Distribution Boards</title>
		<link>https://nelvinelectrical.com.au/distribution-boards/</link>
		
		<dc:creator><![CDATA[fiona]]></dc:creator>
		<pubDate>Mon, 03 Dec 2018 11:43:39 +0000</pubDate>
				<category><![CDATA[Specialist Services]]></category>
		<guid isPermaLink="false">http://nelvinelectrical.com.au/?p=398</guid>

					<description><![CDATA[<p>Inspection on Distribution Switch boards and Motor control panels is an essential and important part of Electrical safety and Compliance. The AS/NZS 3000, covers many of the Regulations about electrical installations state that “Licensed electricians must test all new electrical installations and any modifications to existing installations, including repairs, before putting them into service or [&#8230;]</p>
<p>The post <a href="https://nelvinelectrical.com.au/distribution-boards/">Distribution Boards</a> appeared first on <a href="https://nelvinelectrical.com.au">Nelvin Electrical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Inspection on Distribution Switch boards and Motor control panels is an essential and important part of Electrical safety and Compliance.</p>
<p>The AS/NZS 3000, covers many of the Regulations about electrical installations state that “Licensed electricians must test all new electrical installations and any modifications to existing installations, including repairs, before putting them into service or use”. This is to verify that the installations comply with the requirements of the Australian Standard where applicable.</p>
<p><strong>Testing Electrical Installations</strong></p>
<p>When testing an electrical installation for compliance all parts of the installation, such as switchboards, sub-mains or outbuildings, must be inspected and tested for a full verification of the installation. Some of the inspections Nelvin Electrical will carry out on Switch boards, Distribution Boards &amp; Motor Control Centers (MCC’s) are:</p>
<ul>
<li style="padding-left: 30px;">A thorough visual Inspection will involve inspecting at the switch board panel condition, wiring, doors &amp; locks and distribution board legend.</li>
<li style="padding-left: 30px;">We will also carry out an Infrared Thermography Inspection to detect any thermal anomalies.</li>
<li style="padding-left: 30px;">An earth loop impedance test will be carried out.</li>
<li style="padding-left: 30px;">Statutory RCD Testing.</li>
</ul>
<p>The post <a href="https://nelvinelectrical.com.au/distribution-boards/">Distribution Boards</a> appeared first on <a href="https://nelvinelectrical.com.au">Nelvin Electrical</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Infrared Thermography</title>
		<link>https://nelvinelectrical.com.au/infrared-thermography/</link>
		
		<dc:creator><![CDATA[fiona]]></dc:creator>
		<pubDate>Sun, 03 Dec 2017 21:00:54 +0000</pubDate>
				<category><![CDATA[Specialist Services]]></category>
		<guid isPermaLink="false">http://nelvinelectrical.com.au/?p=393</guid>

					<description><![CDATA[<p>Infrared Thermography is a method of using an Infrared Camera for inspecting. The Infrared Thermal camera records the intensity of radiation emitted from objects in the infrared part of the electromagnetic Spectrum. This radiation is not visible to the naked eye. The camera converts it to a visible image which we can use as a predictive/preventative maintenance tool. It helps [&#8230;]</p>
<p>The post <a href="https://nelvinelectrical.com.au/infrared-thermography/">Infrared Thermography</a> appeared first on <a href="https://nelvinelectrical.com.au">Nelvin Electrical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Infrared Thermography is a method of using an Infrared Camera for inspecting. The Infrared Thermal camera records the intensity of radiation emitted from objects in the infrared part of the electromagnetic Spectrum. This radiation is not visible to the naked eye. The camera converts it to a visible image which we can use as a predictive/preventative maintenance tool. It helps a Trained Thermographer identify and prevent faults prematurely before catastrophic failure. Regular thermography inspections prevent unwanted costly breakdowns and repairs.</p>
<p>Thermography is an extremely effective and very unique inspection method as its non-destructive and non-intrusive, meaning inspections can be conducted while plant and equipment is fully operational.Thermographic inspections are essential for preventative maintenance programs.</p>
<p>Infrared Thermography can be used in numerous fields, the most common being:</p>
<ul>
<li><strong>Electrica</strong>l (electrical panels, switchboards , power lines, equipment) ,</li>
<li><strong>Mechanical</strong> ( motors, gearboxes, bearings, conveyors)</li>
<li><strong>Buildings</strong> ( heat/cooling losses, insulation breakdown, leakage)</li>
<li><strong>Pipe work Tanks </strong>(leakages. Blockages, levels )</li>
</ul>
<p><b class=""><span class="" lang="EN-US">For any more information regarding Infrared Thermography Inspections please feel free to contact <a href="https://nelvinelectrical.com.au/contact/">Nelvin Electrical </a></span></b></p>
<p>The post <a href="https://nelvinelectrical.com.au/infrared-thermography/">Infrared Thermography</a> appeared first on <a href="https://nelvinelectrical.com.au">Nelvin Electrical</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Power Factor Correction Testing</title>
		<link>https://nelvinelectrical.com.au/power-factor-correction/</link>
		
		<dc:creator><![CDATA[fiona]]></dc:creator>
		<pubDate>Sun, 03 Dec 2017 20:25:06 +0000</pubDate>
				<category><![CDATA[Specialist Services]]></category>
		<guid isPermaLink="false">http://nelvinelectrical.com.au/?p=508</guid>

					<description><![CDATA[<p>Power factor is the ratio between the kW and the kVA drawn by an electrical load where the kW is the actual load power and the kVA is the apparent load power The power factor in an electrical system is reduced as more inductive load is applied into that system. The PFC unit automatically connects [&#8230;]</p>
<p>The post <a href="https://nelvinelectrical.com.au/power-factor-correction/">Power Factor Correction Testing</a> appeared first on <a href="https://nelvinelectrical.com.au">Nelvin Electrical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Power factor is the ratio between the kW and the kVA drawn by an electrical load where the kW is the actual load power and the kVA is the apparent load power</p>
<p>The power factor in an electrical system is reduced as more inductive load is applied into that system. The PFC unit automatically connects suitably sized switched capacitors into the power distribution circuit and the Power Factor is improved (closer to unity PF= 1)</p>
<p>The benefits of having a good power factor are</p>
<p>• Reduction of electricity bills<br />
• Extra kVA available from the existing supply<br />
• Reduction of voltage drop in long cables.<br />
• Extended equipment life<br />
• Reduced electrical burden on cables &amp; equipment<br />
• Reduction of power</p>
<p>Regular inspection and servicing of this equipment is essential as equipment failure can lead to fires within the units which could have devastating and costly results.</p>
<p>Nelvin Electrical will carry out a thorough inspection of your power factor units. We will ensure that the controller is set up correctly and that the capacitors are functioning correctly.</p>
<p>We are also able to carry out a full service and repairs to the PFC system.</p>
<p>The post <a href="https://nelvinelectrical.com.au/power-factor-correction/">Power Factor Correction Testing</a> appeared first on <a href="https://nelvinelectrical.com.au">Nelvin Electrical</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Test and Tag</title>
		<link>https://nelvinelectrical.com.au/test-tag/</link>
		
		<dc:creator><![CDATA[fiona]]></dc:creator>
		<pubDate>Tue, 07 Nov 2017 11:54:35 +0000</pubDate>
				<category><![CDATA[Compliance]]></category>
		<guid isPermaLink="false">http://nelvinelectrical.com.au/?p=411</guid>

					<description><![CDATA[<p>Test &#38; Tag (Portable Appliance Testing) The AS/NZS 3760 is the Australian Standard that provides guidelines and regulations for the Test and Tag with regards to electrical safety of appliances. It sets our recommendations to issues such as test and tag intervals, defines who can test and tag and general recommendations. The Test involves inspecting [&#8230;]</p>
<p>The post <a href="https://nelvinelectrical.com.au/test-tag/">Test and Tag</a> appeared first on <a href="https://nelvinelectrical.com.au">Nelvin Electrical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><u>Test &amp; Tag (Portable Appliance Testing) </u></p>
<p>The <a href="http://www.testandtagtraining.com.au/as-nzs-3760">AS/NZS 3760</a> is the Australian Standard that provides guidelines and regulations for the Test and Tag with regards to electrical safety of appliances. It sets our recommendations to issues such as test and tag intervals, defines who can test and tag and general recommendations. The Test involves inspecting the appliance for any damage, followed by electrically testing it with a Portable Appliance Tester. A Tag is placed on the appliance to confirm that it has in fact been tested, along with showing who tested it, the test date and when the next test is due.  All employers have a duty of care to ensure the safety of its employees, meaning that if someone was hurt from an appliance that wasn’t tested and unsafe, they could be found liable.</p>
<p>The post <a href="https://nelvinelectrical.com.au/test-tag/">Test and Tag</a> appeared first on <a href="https://nelvinelectrical.com.au">Nelvin Electrical</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Residual Current Device (RCD)- Safety Switches</title>
		<link>https://nelvinelectrical.com.au/residual-current-device/</link>
		
		<dc:creator><![CDATA[fiona]]></dc:creator>
		<pubDate>Tue, 07 Nov 2017 11:50:22 +0000</pubDate>
				<category><![CDATA[Compliance]]></category>
		<guid isPermaLink="false">http://nelvinelectrical.com.au/?p=408</guid>

					<description><![CDATA[<p>Residual Current Device (RCD) testing requirement for electrical equipment are covered under AS/NZS 3760:2010 &#38; AS/NZS 3012:2010 standards.  An RCD (Residual Current Device) is a safety device that disconnects an electrical circuit when it detects an imbalance of the electric current. RCD’s provide a means of early fault detection. The RCD turns the power off almost [&#8230;]</p>
<p>The post <a href="https://nelvinelectrical.com.au/residual-current-device/">Residual Current Device (RCD)- Safety Switches</a> appeared first on <a href="https://nelvinelectrical.com.au">Nelvin Electrical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><span class="" lang="EN-US">Residual Current Device (RCD) testing requirement for electrical equipment are covered under AS/NZS 3760:2010 &amp; AS/NZS 3012:2010 standards. </span><span class="" lang="EN-US"> An RCD (Residual Current Device) is a safety device that disconnects an electrical circuit when it detects an imbalance of the electric current. RCD’s provide a means of early fault detection. The RCD turns the power off almost immediately to prevent electrocution and reducing the risk of serious injury. RCDs also protect against fire caused by faults in appliance, tools and wiring. If these devices are faulty and not tested they could cause a fire, or personal injury. By law most work places have a Residual Current Device (RCD) testing requirement for electrical equipment under AS/NZS 3760:2010 &amp; AS/NSZ3012:2010 standards.</span></p>
<p>The post <a href="https://nelvinelectrical.com.au/residual-current-device/">Residual Current Device (RCD)- Safety Switches</a> appeared first on <a href="https://nelvinelectrical.com.au">Nelvin Electrical</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Emergency Exits and Smoke Detectors</title>
		<link>https://nelvinelectrical.com.au/emergency-exits-and-smoke-detectors/</link>
		
		<dc:creator><![CDATA[fiona]]></dc:creator>
		<pubDate>Tue, 07 Nov 2017 11:48:09 +0000</pubDate>
				<category><![CDATA[Compliance]]></category>
		<guid isPermaLink="false">http://nelvinelectrical.com.au/?p=405</guid>

					<description><![CDATA[<p>Australian Standard AS/NZS 2293.2 1995 relates to inspection and maintenance of Emergency &#38; Evacuation lighting for buildings. Emergency lighting is an essential service that is quite often forgotten, until an accident or catastrophe happens in the event the power fails in your building, your emergency and exit lights must remain lit for at least 90 [&#8230;]</p>
<p>The post <a href="https://nelvinelectrical.com.au/emergency-exits-and-smoke-detectors/">Emergency Exits and Smoke Detectors</a> appeared first on <a href="https://nelvinelectrical.com.au">Nelvin Electrical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Australian Standard AS/NZS 2293.2 1995 relates to inspection and maintenance of Emergency &amp; Evacuation lighting for buildings. Emergency lighting is an essential service that is quite often forgotten, until an accident or catastrophe happens in the event the power fails in your building, your emergency and exit lights must remain lit for at least 90 minutes, to allow people safe passage out of the building. It is imperative to maintain all emergency and exit lighting in commercial buildings, to comply with relevant building codes in accordance with Australian Standards (AS/NZS 2293.2).</p>
<p>Not only will you comply with exit testing regulations, but you will have greater peace of mind in knowing that your emergency exit lighting and smoke detectors is fully operative.</p>
<p>The post <a href="https://nelvinelectrical.com.au/emergency-exits-and-smoke-detectors/">Emergency Exits and Smoke Detectors</a> appeared first on <a href="https://nelvinelectrical.com.au">Nelvin Electrical</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Microwave oven leakage testing</title>
		<link>https://nelvinelectrical.com.au/microwave-oven-leakage-testing/</link>
		
		<dc:creator><![CDATA[fiona]]></dc:creator>
		<pubDate>Tue, 07 Nov 2017 11:45:22 +0000</pubDate>
				<category><![CDATA[Compliance]]></category>
		<guid isPermaLink="false">http://nelvinelectrical.com.au/?p=402</guid>

					<description><![CDATA[<p>This is a very simple and relatively cheap inspection service which is becoming very popular to prevent any injuries caused by microwave radiation leakage. AS/NZS 60335.2.25 is the Electrical Regulations which cover Microwave Oven Leakage Testing. Industry employers have a “Duty of Care”, to ensure their workplace is safe, and we suggest the testing of [&#8230;]</p>
<p>The post <a href="https://nelvinelectrical.com.au/microwave-oven-leakage-testing/">Microwave oven leakage testing</a> appeared first on <a href="https://nelvinelectrical.com.au">Nelvin Electrical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>This is a very simple and relatively cheap inspection service which is becoming very popular to prevent any injuries caused by microwave radiation leakage. AS/NZS 60335.2.25 is the Electrical Regulations which cover Microwave Oven Leakage Testing.</p>
<p>Industry employers have a “Duty of Care”, to ensure their workplace is safe, and we suggest the testing of microwave ovens in the workplace annually as a minimum standard. This standard states that the microwave leakage power flux density of microwave radiation from any microwave oven shall not exceed 50W/m2 (5mW/cm2) or more from the external surface of the oven .The Microwave Oven is inspected for any physical damage to ensure safety and compliance.</p>
<p>The post <a href="https://nelvinelectrical.com.au/microwave-oven-leakage-testing/">Microwave oven leakage testing</a> appeared first on <a href="https://nelvinelectrical.com.au">Nelvin Electrical</a>.</p>
]]></content:encoded>
					
		
		